ID 176563 - ReadGeo alembic results with UV projection do not match for the same Nuke internal geometry or .fbx

Follow

Problem summary
ReadGeo alembic results with UV projection do not match for the same Nuke internal geometry ( e.g.  cylinder) or .fbx file

Customer reported version
nuke.9.0v7

Customer reported platform

Linux version 2.6.32-431.3.1.el6.x86_64  gcc version 4.4.7 20120313 (Red Hat 4.4.7-4)

 
REPRO:
use attached TF_repro.nk

-with a WriteGeo1 node write out the geometry as Alembic (abc) 
-with a ReadGeo13 node load in the file you just created 
-with a WriteGeo2 node write out the geometry as Alembic (abc) 
-with a ReadGeo1 node load in the file you just created 
-View ScanlineRender in either projection mode perspective or uv
-Change Switch node to [0 to see cylinder, 1 to see .abc and 2 to see .fbx] and compare the output of ScanlineRenderer
 
0=Cylinder (Nuke internal geometry) 
1= ReadGeo .abc (rendered from Cylinder) 
2= ReadGeo.fbx  (rendered from Cylinder) 
 
RESULT- for ReadGeo .abc  (on Switch=1) does not match results for .fbx or Nuke internal geometry (a cylinder)
All three should match, but .abc does not.
 
see screenshots :
fbx_result.png 
abc_result.png
 
 
 
NOTE: also attached are customer's files, which contain some python customization,
but would use the same repro steps
F_ldev_pipe_comp_alembicCheck_v001_01.nk
customer screenshots-
dev_pipe_geo_v001.abc 
dev_pipe_geo_v001.fbx 
 
 

Reproduced by support
8.0v6-10.0v3 same incorrect result ( for earlier versions, comparison results vary but still, none are correct)

MacOS 10.10.4

Expected behaviour

ReadGeo alembic results with UV projection should match for the same Nuke internal geometry ( a cylinder)  or .fbx file

 

Actual behaviour

ReadGeo alembic results with UV projection do not match for the same Nuke internal geometry ( a cylinder) or .fbx file

 
 

    We're sorry to hear that

    Please tell us why