State:Closed|icon_bug|icon_nuke|database:public|Resolution:Fixed|TargetRelease:11.0v3|BugID:253659|
This is happening in Nuke10.5v2 in Linux RHEL 6.5
This is a regression
Summary of the problem
Full resolution stereo in the monitor output tool is sending out inverted colours
To test this properly please use an Aja Kona 3G with the correct drivers installed and a broadcast monitor.
Repro steps
- Open nuke studio
- Go to edit settings and activate the stereo views
- Import stereo exr files from /mnt/netqa/Testing/Nuke/Shotsbycategory/Stereo/avatar/s022_040_bg1022tk00p002c_hdf950scan1080_v02/
- Drag this clip on the timeline.
- Open the monitor output tool. Select the video card and change Single to Resolution stereo.
- Now connect both SDI outputs with BNC cables from the video card (Aja Kona 3G) to input 1 and 2 to the JVC monitor.
- You will see the images on the monitor has something similar to a sepia toned image. The blue colours are inverted.
- Press 2 on the JVC monitor to see the right eye. (It can be found on bottom right corner.)
- The image will be same as input 1.
Reproduced in
10.5v2
10.5v1
10.0v6
10.0v5
10.0v1
Workaround
Going back to Single view on the monitor output tool. The left and right eye can be chosen but will be coming through a single BNC.
Actual result
A washed up orange sepia toned image.
Expected result
Actual picture representation from Nuke viewer straight to the monitor.