ID 317714 - Nuke 11 releases do not refresh the curve display in the GUI when scrolling (Mac only)

Follow

Problem summary
Nuke 11.0v1 and 11.0v2 releases do not refresh the curve display in any of its GUI related tools. eg. HueCorrect, ColorLookup when scrolling in the Properties Bin.
This is only occuring in MacOS 

Customer reported version
nuke.11.0v2

Customer reported platform
MacOS 10.13 (High Sierra)

Steps to reproduce

1) Open up Nuke 11.0v1 or 11.0v2 in your Mac environment

2) Create two 'ColorCorrect's (or any node that has quite alot of settings in the properties bin)

3) Click 's' hotkey in the Node Graph to open up the 'Project Settings' panel in the 'Properties' bin

4) Click the 'Color' tab and scroll up and down in the properties window
Result: The LookupCurve display will not update automatically in the GUI

Workaround
The suggested workaround is to click inside the curve display window and it will refresh temporarily, until scrolling happens again.

Reproduced by support
This bug has been reproduced in:
Nuke 11.0v2 - MacOSX 10.12
Nuke 11.0v1 - MacOSX 10.12 - regression

Unable to reproduce bug in:
Nuke 11.0v2 - Windows 7 - CentOS 6.9
Nuke 11.0v1 - Windows 7 - CentOS 6.9
Nuke 10.5v6 - MacOSX 10.12 - Windows 7 - CentOS 6.9

Earliest version tested:
Nuke 10.5v6
- This issue no longer appears in this version and has regressed

Expected behaviour
GUI should automatically refresh the curve display when scrolling

Actual behaviour
GUI doesn't refresh the curve display when scrolling
 

    We're sorry to hear that

    Please tell us why