ID 408914 - [C] Export: path does not update after first export when using sequence_revision chip

Follow

Problem summary
After exporting a Sequence Revision, exporting a different Revision will result in the files being saved in the previous Revision directory.

 

Customer reported version
Flix 6.1.2

 

Customer reported platform
macOS 10.13

 

Steps to reproduce

1) In Preferences>Exporting set export path to ...\[sequence_tracking_code]_[sequence_revision] using the provided chips at the bottom, so that every Sequence Revision has its own separate folder for exported media.



2) Navigate to any Sequence Revision and export any media.


3) Select any panel in the Revision and click on Make a new version at the bottom left corner.
 

4) Click on Save Revision at the top to create a new Sequence Revision.

 

5) Export any media

 

6) Export path will not have updated and files will be saved in the previous Revision directory

 

Expected behaviour
The chip for sequence_revision should update to match the Sequence Revision the user is exporting from

 

Actual behaviour
The chip in the export path does not update and exported files are saved in previous Sequence Revision export directory

 

Workaround
Reload Flix Client (at the top click View>Reload) before exporting a new Revision.

 

Reproduced by support

This bug has been reproduced in:

Flix 6.1.2 - Windows 10 - macOS 10.14

Flix 6.1.1 - Windows 10

Flix 6.1.0 - Windows 10 - macOS 10.14

 

Earliest version tested
Flix 6.1.0 - This feature did not exist before this version

 

 

    We're sorry to hear that

    Please tell us why