ID 432414 - The knobs are not reset when executing the Load settings from metadata knob with an outside frame range of the ARI file.

Follow

Problem summary
The knobs are not reset when executing the Load settings from metadata knob with an outside frame range of the ARI file.

 

Customer reported version
nuke.12.1v2

 

Customer reported platform
centos7

 

Steps to reproduce

1) Download the following footage: https://arriwebgate.com/directlink/b350ec256c1ca19b/1378552

2) Open Nuke and import the footage.

3) Add a FrameHold node and set it for a value outside of the current frame range of the footage.

4) Open the Properties of the Read node and click the dropdown for Clip Settings.

5) Drag the slider of the Exposure Index(ISO) to increase the value.

6) Select the "Load settings from metadata" knob, and view any changes made.

 

Expected behavior
The ISO settings should revert to the metadata settings for the Read node.

 

Actual behavior
The settings are not reverted back to the original metadata settings.

 

Workaround
Having the frames inside the frame range allows the values to be reset without issue.

 

Reproduced by Support in
Nuke 12.1v2 - Windows 10

Nuke 12.1v1 - Windows 10

 

Earliest version tested
Nuke 12.0v6 - This feature did not exist before this version

 

    We're sorry to hear that

    Please tell us why