ID 462108 - Instanced Channel Relationship node doesn't output the correct values.

Follow

Problem summary
Instanced Channel Relationship node doesn't output the correct values.

Customer reported version
modo.14.2v1

Customer reported platform
windows10

Steps to reproduce
1) Launch Modo.
2) Select File > Open from the menu bar and open the attached .lxo file.
3) Select Layout > Layouts > Setup from the menu bar.
4) Navigate to the Node Graph and click on the Channel Relationship node.
5) Right click on the node and select Node Duplicate > Instance
6) Disconnect the original relationship node from Capsule (2) output.
7) Connect the output connector from the instanced Channel Relationship node to the Capsule (2) "Rotation X" input.
8) Scrub the timeline between frame 0 and frame 24.
Result: "Capsule" rotates more than "Capsule (2)".


Expected behaviour
The instanced copy of the channel relationship node should cause the same behavior to the output as the original node.

Actual behaviour
The instanced copy does not affect changes to the output until the project file is closed and reopened.

Workaround
Unknown. 

Reproduced by support
14.2v1 - Windows 10
14.1v2 - Windows 10
14.1v1 - Windows 10
14.0v2 - Windows 10
14.0v1 - Windows 10
13.2v1 - Windows 10
13.1v1 - Windows 10
13.0v1 - Windows 10
12.2v2 - Windows 10



Earliest version tested

Modo 12.2v2
 

    We're sorry to hear that

    Please tell us why