ID 467431 - Key Nominated knob within O_Solver node provides an error message when executed in Ocula 4.0

Follow

Problem summary
Within the O_Solver node, it is possible to key the analysis of the solve at specific frames using the 'Key Nominated' option.

It has been discovered that in Nuke 11.2v4 and later releases (using Ocula 4.0), that selecting and running the 'Key Nominated' option creates an error message (see below)



Note: This does not occur in Nuke 11.2v3 releases and earlier


Customer reported version

Customer reported platform
windows10

Steps to reproduce

1) In a new Nuke session (11.2v4 or later), Create or import a script that contains stereo footage in a stereoscopic (left/right) setup

2) Create an O_Solver node in the tree under the footage

3) Within the O_Solver node properties bin, select the 'Key Nominated' option
Result: above error message

Expected behaviour
Executing the 'Key Nominated' knob should bring up a render selection menu and execute for the specific frames

Actual behaviour
Executing the knob provides an error message

Workaround
Unknown, use either 'Keyframe' or 'Key Sequence' options if possible.

Reproduced by support
This bug has been reproduced in:
Nuke 12.2v5 - Windows 10 - MacOS 10.15.6 - CentOS 7
Nuke 12.2v1 - Windows 10
Nuke 12.1v1 - Windows 10
Nuke 12.0v1 - Windows 10
Nuke 11.3v1 - Windows 10
Nuke 11.2v4 - Windows 10 - MacOS - CentOS 7 - regression

Unable to reproduce bug in:
Nuke 11.2v3 - Windows 10 - MacOS - CentOS 7

Earliest version tested
Nuke 11.2v3
- This issue doesn't appear in this version and has regressed

    We're sorry to hear that

    Please tell us why