State:Closed|icon_bug|icon_nuke|database:public|Resolution:Fixed|TargetRelease:13.2v3|BugID:507829|
Problem summary
Switching between the Timeline and Node Graph while using monitor out is now very cumbersome.
Customer reported version
nuke.13.2v1
Customer reported platform
linux
Steps to reproduce
1) Open Nuke Studio, import some footage and add it to the timeline
2) Open the Viewer Monitor Out Panel, and set the device to Monitor Out hardware, like a AJA or Blackmagic card, setting the display mode and pixel format to something custom.
3) Switch to the Node Graph and create a CheckerBoard node and view it, the Monitor Out display does not update with the new image. If you do enable monitor out on the viewer node, then is does not retain the settings from the timeline.
Expected behaviour
For the active timeline/node graph to be switched to as it changes.
Actual behaviour
The output on the Monitor Out display does not update.
Workaround
1) In the Viewer Monitor Out panel, select the Timeline Viewer
2) Open the advanced setting in the Properties panel, and take note of the Output Setup
4) Disable Monitor Out for the Timeline Viewer
5) Goto the Viewer Monitor Out panel, select the Viewer1 (NUKE)
6) Open the advanced setting in the Properties panel, and apply the same settings from the Timeline Viewer Output Setup
7) Enable Monitor Out for the Nuke Viewer
Reproduced by support
This bug has been reproduced in:
Nuke Studio 13.2v1 - Windows 10 - regression
Unable to reproduce bug in:
Nuke Studio 13.1v3 - Windows 10
Earliest version tested
Nuke Studio 13.1v3 - This issue doesn't appear in this version and has regressed
We're sorry to hear that
Please tell us why