ID 564083 - Collector/Emitter nodes Position channels do not work when Position (Read only) channels are also present.

Follow

Problem summary
Collector/Emitter nodes Position channels do not work when Position (Read only) channels are also present.
 
Customer reported version
modo.16.1v8
 
Customer reported platform
mac.14
 
Steps to reproduce
 
1) Download the attached file.

2) Run the simulation and notice new particles are not being emitted at the points of collision.

3) Go to the Schematic Viewport and select the Collector/Emitter node.
 
4) Go to the Properties tab and select Remove Feature... select the Position (Read Only) option and select OK. Notice that the new particles are now being created as expected.
 
Expected behaviour
The Position channel should still work correctly when Position (Read Only) channels exist.
 
Actual behaviour
Position channels do not work when Position (Read Only) channels are also present.
 
Workaround
The Position (Read Only) channels will need to be removed.
 
Reproduced by support
This bug has been reproduced in:
16.1v8 - macOS 13.5, Windows 10
15.0v1 - macOS 13.5, Windows 10
 
Earliest version tested
15.0v1 - This issue appears to be in all tested versions of the product.

    We're sorry to hear that

    Please tell us why